The new double dome constructions provides lower offsets and cosine errors. The MS-60 can be used with the optional MV-01 ventilator / heater.
The MS-60 pyranometers are manufactured in a consistent way followed by strict quality inspection and performance evaluation. EKO provides a unique calibration compliant to the international standards defined by ISO/IEC17025/9847.
The sensor has a 5 years warranty with a 2 years re-calibration interval recommended and it is no longer necessary to change the desiccant.
| Classification | ISO 9060 First Class |
|---|---|
| Output | Voltage (mV) |
| Sensitivity | 7 ... 16 µV/W/m-2 |
| Resolution | - |
| Wavelength range | 285 ... 3000 nm |
| Max. irradiance | 2000 W/m2 |
| Response time (95%) | < 18 s |
| Zero offset (a) thermal radiation (200 W/m²) (b) temperature change (5k/hr) |
< 5 W/m² ± 2 W/m² |
| Non-linearity @ 1000 W/m² | ± 1 % |
| Non-stability change/1 year | ± 1.5 % |
| Direction response @ 1000 W/m² | ± 18 W/m² |
| Temperature response (-10 ... +40°C) | < 3 % |
| Temperature response (-20 ... +50°C) | < 4 % |
| Tilt response @ 1000 W/m² | ± 1 % |
| Impedance @ 25°C | 60 ... 100 Ω |
| Operating temperature | -40 ... +80 °C |
| Power supply | |
| Power consumption | |
| Cable length | 10 m |
| Weight | 0.35 kg |
| Protection class | IP67 |
| Warranty | 5 years |
| Manufacturer | EKO Instruments |
| Accessory | |
| MV-01 ventilator / heater (Order-No. S64060) |
Delivery includes IEC 17025 calibration certificate.
| Sensor | Wire Colour (EKO) | Meteo-40 Analog Voltage |
|---|---|---|
| Solar irradiance Output voltage |
brown (+) | Ax |
| white (-) | Bx | |
| shield | Earth |