The module M83200 converts AC signal inputs into pulse outputs and provides configurable 5 V outputs.
The module M83200 contains:
Electrical characteristics (Default settings) | ||||
---|---|---|---|---|
Parameter | Pin / Ports | Min | Typical | Max |
Supply voltage (DC) Quiescent current |
13 | 9 V 11 mA |
32 V 16 mA |
|
Ground GND | 15 | |||
Configurable Outputs | ||||
Output (5 V DC) (ϑ = 25°C) | 14, 16 | 5.2 V 110 mA |
5.8 V 130 mA |
|
Pull-up current limit 1 mA (Low current configuration 5.1 kΩ) |
14, 16 | 0.97 mA | 1.05 mA | |
Pull-up current limit 10 mA (High current configuration) |
14, 16 | 10.5 mA | 11.4 mA | |
AC Voltage Converters | ||||
Input sensitivity of converter | 2, 3, 6, 7 | 115 mV | 120 mV | |
Ground GND | 4, 8 | |||
Output level low | 9, 10, 11, 12 | 0 V | 0.01 V | |
Output level high | 9, 10, 11, 12 | 5 V | 5.8 V | |
Operating temperature | -40°C | +75°C | ||
Fuse T0.8A (time lag, slow-blow): 5 x 20 mm |
Housing dimension (width x height x depth): 22.5 x 110 x 115 mm
Mounting on DIN-rail (35 x 7.5 mm)
Terminal: wire cross section from 0.25 to 1.5 mm²
Terminal Earth: recommended wire cross section 1.5 mm²
(Keep wire length as short as possible)