The MS-80 Secondary Standard pyranometer was inspired by the combination of latest technologies and state-of-the-art thermopile sensors, enabling a breakthrough in unprecedented low zero-offset behaviour and fast sensor response. The compact sensor with single dome, based on a isolated thermopile detector and Quartz diffusor is immune to offsets and integrates all optional value added functions such as a ventilator, heater and different industrial interfaces. The heater and ventilator are recommended, particularly over areas impacted by dew, frost, snow, and dust.
MS-80 is designed with analog voltage output. The analogue MS-80 pyranometer can be used as a reference sensor to measure the global broad-band solar radiation with a high accuracy. With excellent temperature response and non-linearity characteristics, it provides optimal performance throughout the year.
Classification | ISO 9060 Secondary Standard |
---|---|
Output | Voltage (mV) |
Sensitivity | ~ 10 µV/W/m-2 |
Resolution | - |
Wavelength range | 285 ... 3000 nm |
Max. operational irradiance | 4000 W/m² |
Response time (95%) | < 0.5 s |
Response time (99%) | < 1 s |
Zero offset (a) thermal radiation (200 W/m²) (b) temperature change (5k/hr) |
1 W/m² ± 1 W/m² |
Non-linearity | ± 0.2 % |
Long-term stability | ± 0.5 % / 5 years |
Direction response | ± 10 W/m² |
Temperature response (-20 ... +50°C) | < 1 % |
Tilt response @ 1000 W/m² | ± 0.2 % |
Impedance | approx. 45 kΩ |
Operating temperature | -40 ... +80 °C |
Power supply | |
Power consumption | |
Cable length | 10 m |
Weight | 0.4 kg |
Protection class | IP67 |
Warranty | 5 years |
Manufacturer | EKO Instruments |
Accessory | Thies Universal Amplifier (Order-No. S05000) |
MV-01 ventilator / heater (Order-No. S64060) |
Delivery includes IEC 17025 calibration certificate.